Parameter Dictionary Parameters
Bits Description
If set, an index position has been captured. Cleared when the captured position is read.
If set, a new index transition occurred when a captured position was already stored.
Depending on the mode, the new position may have been discarded, or overwritten the
previously stored position.
If set, a home position has been captured. This bit is cleared when the captured position is
read.
If set, a new home pin transition occurred when a captured position was already stored.
Depending on the mode, the new position may have been discarded, or overwritten the
previously stored position.
New high speed capture data if set.
High speed capture overflow if set.
Number of Resolver Cycles/Motor Rev. This parameter is only used with resolver
feedback devices.
PWM Mode and Status. Bit-mapped as follows:
Force bus clamping if set, disable bus clamping if clear. If bit 1 is set, then this bit is ignored.
Automatic bus clamping mode if set. Setting this bit causes bus clamping mode to be
automatically selected based on the output voltage. Bit 0 is ignored if this bit is set
Factory reserved. If set, DBrk mode is enabled.
Use hexagonal voltage limiting if set, circular limiting if clear. This setting is only used with
brushless motors.
1. Double PWM frequency if set.
3. Status bit, set when bus clamping is active.
For notes on Output numbering see Input/Output Numbering.
Data type is dependent on configuration and uses 1 to 5 words.
Copley Controls Page 24