Wiring Xenus XTL User Guide
52 Copley Controls Corp.
4.5: Logic Supply / Brake (J4)
Mating Connector
Description Euro-style, 3 position, 5.0 mm pluggable female terminal block.
Manufacturer PN Wago: 51117974 or 721-103/026-047/RN01-0000
Wire Size 22 - 14 AWG
Recommended Wire 18 AWG
Wire Insertion/Extraction Tool Wago: 231-131
Standard connector and tool are included in connector kit XTL-CK or XTL-CA
Pin Description
Pin Signal Function
1 RTN +24 Vdc return
2 Brake Return or low side of motor brake
3 +24 Vdc +24 Vdc Logic power supply
Logic Supply / Brake Wiring Diagram
Amplifier J4
Isolated Logic
Power Supply
+24 V
Brake
RTN
Brake
+24 Vdc
Power
Supply
(Required)
J4-1
J4-2
J4-3