CME 2 User Guide Digital Inputs and Outputs
Copley Controls 61
6.2.3: Custom Digital Output Settings: Custom Event
Any of the amplifier’s digital outputs can be programmed to respond to a combination of
events including faults, warnings, and status indications. The output goes active when one
or more of the selected events take place.
Configure a Custom Event output
Choose Custom Event for an output and then click Configure Custom to open the
Event Configuration screen.
Select one or more Custom Event Functions (p. 62).
Multiple functions are OR’ed together, so any event activates the output.
Choose Output Active Hi/Off or Output Active Lo/On.
To latch the output, set the Latch Output option.
The Clear button clears all check marks.
Latching an output does not eliminate the risk of unexpected motion with
non-latched faults.
Associating a fault with a latched, custom-configured output does not latch the
fault itself. After the cause of a non-latched fault is corrected, the amplifier re-
enables without operator intervention. In this case, motion may re-start
unexpectedly.
Failure to heed this warning can cause equipment damage, injury, or death.
Click OK to save changes to amplifier RAM and close the screen.